    FailureQA
Failure Q&A
Abnormality Cause Troubleshooting
Impervious cutting, rough tool edge 1. Askew light path
2. Lens pollution
3. Incorrect focus length and focalizing
1. Correct the light path
2. Clean the lens
3. Readjust the focus length
 
Deformed circle,  mismatching starting and ending points of closed line
  1. Loose bolts of small and big gear wheels on transmitting shaft.
  2. loose X.Y axis belt.
  1. Refix the bolts firmly.
  2.  Adjust the screw of the belt.
 
Carving dislocation
  1. Ground wire is not in good earthing.
  2. The computer is installed with network card and anti-virus software.
  3. Unstable computer system
  1. Check the ground wire and ensure it is in good condition.
  2. Disable the network card and antivirus software.
  3. Reinstall the operating system.
Superfluous carving There is unclosed or crossing places between  pictographs and lines Modify the pictographs and make the lines closed without crossing
 No power when turn on the main switch
  1. Air switch is switched on
  2. Fuse is burnt.
  3. The urgent stop button is pressed down
  1. switch on the air switch
  2. Change the fuse
  3.  Turn on the urgent stop button.
non-operative  but vibrating motor The wire of the motor is disconnected or wrongly connected. Check and repair the wire
Unstable machine tool 1.Mismatching main board 1. Change the main board
No laser
  1. High voltage laser and the two ends of the laser tube are not connected
  2. Too little current
  1. Take out the high voltage laser, and connect the two ends.
  2. Reset the current
Sudden ringing of  retainer; machine halt
  1. Incorrect zero point or over large graphics
  2. X,Y axis are at the position of the retainer , and make it ring.
  1. Reset the zero point and modify the graphics
  2. Move the X, Y axis.
Manual direction failure and controllable computer direction
  1. Poor connection of the 3rd, 4th, 5th and 6th lines on the FPC 12 of the PCB.
  2. The failure of the direction key of the control panel or disconnected wire
  1. Check and weld the 3rd, 4th,5th,6th lines
  2. Disassemble the control panel and check the direction key and weld the disconnection wire. 